Abstract
One-way slabs under concentrated loads are generally designed for shear by checking the beam shear resistance and the punching shear resistance over an effective width. Only a small number of test data regarding the shear resistance of one-way slabs subjected to concentrated loads is currently available. To be able to better evaluate the shear resistance of one-way slabs, a series of experiments was carried out on continuous one-way slabs (5 m x 2.5 m x 0.3 m [16.4 ft x 8.2 ft x 11.8 in.]) subjected to concentrated loads close to the supports, in which the load position, transverse reinforcement ratio, and concrete strength were varied. The test results are compared with code provisions and a method developed by Regan. The results show a different behavior in shear for slabs under concentrated loads than for beams.
| Original language | English |
|---|---|
| Pages (from-to) | 275-284 |
| Number of pages | 10 |
| Journal | ACI Structural Journal |
| Volume | 110 |
| Issue number | 2 |
| State | Published - Mar 2013 |
| Externally published | Yes |
Keywords
- Effective width
- Experiments
- One-way slabs
- Punching
- Shear.
Fingerprint
Dive into the research topics of 'Shear in one-way slabs under concentrated load close to support'. Together they form a unique fingerprint.Cite this