Association of Stent-Retriever Characteristics in Establishing Successful Reperfusion During Mechanical Thrombectomy: Results from the ESCAPE-NA1 Trial

  • Petra Cimflova
  • , Nishita Singh
  • , Johanna M. Ospel
  • , Martha Marko
  • , Nima Kashani
  • , Arnuv Mayank
  • , Ricardo Hanel
  • , Diogo C. Haussen
  • , Aditya Bharatha
  • , David Volders
  • , Manraj K.S. Heran
  • , Alexandre Y. Poppe
  • , Brian van Adel
  • , Bijoy K. Menon
  • , Manish Joshi
  • , Andrew Demchuk
  • , Ryan McTaggart
  • , Raul G. Nogueira
  • , Jeremy L. Rempel
  • , Charlotte Zerna
  • Michael Tymianski, Michael D. Hill, Mayank Goyal, Mohammed A. Almekhlafi*
*Autor correspondiente de este trabajo
  • University of Calgary
  • Masaryk University
  • University of Basel
  • Medical University of Vienna
  • Baptist Health
  • Emory University
  • University of Toronto
  • Dalhousie University
  • Vancouver General Hospital
  • Centre Hospitalier de L'Universite de Montreal
  • McMaster University
  • Brown University
  • University of Alberta
  • NoNO Inc.

Producción científica: Contribución a una revistaArtículorevisión exhaustiva

6 Citas (Scopus)

Resumen

Background: Successful reperfusion determines the treatment effect of endovascular thrombectomy. We evaluated stent-retriever characteristics and their relation to reperfusion in the ESCAPE-NA1 trial. Methods: Independent re-scoring of reperfusion grade for each attempt was conducted. The following characteristics were evaluated: stent-retriever length and diameter, thrombus position within stent-retriever, bypass effect, deployment in the superior or inferior MCA trunk, use of balloon guide catheter and distal access catheter. Primary outcome was successful reperfusion defined as expanded thrombolysis in cerebral infarction (eTICI) 2b–3 per attempt. The secondary outcome was successful reperfusion eTICI 2b–3 after the first attempt. Separate regression models for each stent-retriever characteristic and an exploratory multivariable modeling to test the impact of all characteristics on successful reperfusion were built. Results: Of 1105 patients in the trial, 809 with the stent-retriever use (1241 attempts) were included in the primary analysis. The stent-retriever was used as the first-line approach in 751 attempts. A successful attempt was associated with thrombus position within the proximal or middle third of the stent (OR 2.06; 95% CI: 1.24–3.40 and OR 1.92; 95% CI: 1.16–3.15 compared to the distal third respectively) and with bypass effect (OR 1.7; 95% CI: 1.07–2.72). Thrombus position within the proximal or middle third (OR 2.80; 95% CI: 1.47–5.35 and OR 2.05; 95% CI: 1.09–3.84, respectively) was associated with first-pass eTICI 2b–3 reperfusion. In the exploratory analysis accounting for all characteristics, bypass effect was the only independent predictor of eTICI 2b–3 reperfusion (OR 1.95; 95% CI: 1.10–3.46). Conclusion: The presence of bypass effect and thrombus positioning within the proximal and middle third of the stent-retriever were strongly associated with successful reperfusion.

Idioma originalInglés
Páginas (desde-hasta)799-807
Número de páginas9
PublicaciónClinical Neuroradiology
Volumen32
N.º3
DOI
EstadoPublicada - sept 2022
Publicado de forma externa

Huella

Profundice en los temas de investigación de 'Association of Stent-Retriever Characteristics in Establishing Successful Reperfusion During Mechanical Thrombectomy: Results from the ESCAPE-NA1 Trial'. En conjunto forman una huella única.

Citar esto