Ir directamente a la navegación principal Ir directamente a la búsqueda Ir directamente al contenido principal

Case Study on Aggregate Interlock Capacity for the Shear Assessment of Cracked Reinforced-Concrete Bridge Cross Sections

  • Eva O.L. Lantsoght*
  • , Cor Van Der Veen
  • , Joost C. Walraven
  • , Ane De Boer
  • *Autor correspondiente de este trabajo
  • Delft University of Technology
  • Ministry of Infrastructure and the Environment

Producción científica: Contribución a una revistaArtículorevisión exhaustiva

26 Citas (Scopus)

Resumen

A 55-year-old bridge showed large cracking in the approach bridge caused by restraint of deformation and support settlement. After repair, it was uncertain at which crack width the traffic loads on the bridge should be further restricted. The shear capacity was calculated by counting on the aggregate interlock capacity of a supposedly fully cracked cross section. An aggregate interlock relationship between shear capacity and crack width based on an unreinforced section was used to find the maximum allowable crack width. Limits for crack widths at which load restrictions should be imposed were found. The large structural capacity of the cracked concrete section shows that the residual bearing resistance based on the aggregate interlock capacity of reinforced concrete slab bridges with existing cracks is higher than expected. This expected capacity could be calculated with the inclined cracking load from the code provisions. The procedure outlined in this paper can thus be used for the shear assessment of fully cracked cross sections of reinforced concrete bridges.

Idioma originalInglés
Número de artículo04016004
PublicaciónJournal of Bridge Engineering
Volumen21
N.º5
DOI
EstadoPublicada - 1 may. 2016

Huella

Profundice en los temas de investigación de 'Case Study on Aggregate Interlock Capacity for the Shear Assessment of Cracked Reinforced-Concrete Bridge Cross Sections'. En conjunto forman una huella única.

Citar esto