T1 - Determinants of immediate failure of noninvasive mechanical ventilation outside the intensive care unit
AU - Briones Claudett, Killen H.
AU - Briones Claudett, Monica H.
AU - Esquinas, Antonio M.
AU - Andrade, Michelle Grunauer
PY - 2017/10/30
Y1 - 2017/10/30
N2 - Background: This study aimed to characterize which are the early determinants of immediate failure of the use of noninvasive mechanical ventilation (NIMV) outside the ICU. Methods: This prospective study included patients who were admitted to the Military Hospital in Guayaquil, Ecuador. Each variable was analyzed independently by using a multiple logistic regression model toward establishing an association with the event. Results: A total of 249 cases of NIMV over a 10 year period of its application outside the ICU was included in the study. Fifty-five (22.10%) patients were transferred to the ICU, A multivariate analysis showed that the determinants of immediate NIMV failure outside the ICU were the following: age (OR: 1.12; P = 0.03); SBP (OR: 1.04; P = 0.001); HR (OR: 1.66; P < 0.0001); pCO 2 (OR: 1.16; P = 0.007); PO 2 (OR: 1.35; P = 0.003); levels of IPAP (OR: 1.35; P < 0.0001); and the number of quadrants affected, as shown in a chest X-ray (OR: 1.40; P < 0.0001). Conclusions: The number of affected quadrants in a chest X-ray, tachyarrhythmia and hypoxemia may be useful in the initial decision in the use of NIMV outside the ICU. High values of IPAP, the persistence of elevated pCO 2 , arterial hypotension, and age could be useful as a second screening associated with immediate NIMV failure outside the ICU.
AB - Background: This study aimed to characterize which are the early determinants of immediate failure of the use of noninvasive mechanical ventilation (NIMV) outside the ICU. Methods: This prospective study included patients who were admitted to the Military Hospital in Guayaquil, Ecuador. Each variable was analyzed independently by using a multiple logistic regression model toward establishing an association with the event. Results: A total of 249 cases of NIMV over a 10 year period of its application outside the ICU was included in the study. Fifty-five (22.10%) patients were transferred to the ICU, A multivariate analysis showed that the determinants of immediate NIMV failure outside the ICU were the following: age (OR: 1.12; P = 0.03); SBP (OR: 1.04; P = 0.001); HR (OR: 1.66; P < 0.0001); pCO 2 (OR: 1.16; P = 0.007); PO 2 (OR: 1.35; P = 0.003); levels of IPAP (OR: 1.35; P < 0.0001); and the number of quadrants affected, as shown in a chest X-ray (OR: 1.40; P < 0.0001). Conclusions: The number of affected quadrants in a chest X-ray, tachyarrhythmia and hypoxemia may be useful in the initial decision in the use of NIMV outside the ICU. High values of IPAP, the persistence of elevated pCO 2 , arterial hypotension, and age could be useful as a second screening associated with immediate NIMV failure outside the ICU.
KW - Intensive care unit
KW - Mechanical ventilation
KW - Noninvasive
KW - Out-of intensive care unit
UR - http://www.scopus.com/inward/record.url?scp=85032749581&partnerID=8YFLogxK
U2 - 10.5603/AIT.a2017.0054
DO - 10.5603/AIT.a2017.0054
M3 - Artículo
C2 - 29027655
AN - SCOPUS:85032749581
SN - 1642-5758
VL - 49
SP - 252
EP - 258
JO - Anaesthesiology Intensive Therapy
JF - Anaesthesiology Intensive Therapy
IS - 4
ER -