TY - JOUR
T1 - In vivo temperature rise and acute inflammatory response in anesthetized human pulp tissue of premolars having Class V preparations after exposure to Polywave® LED light curing units
AU - Gross, Dayane Jaqueline
AU - Dávila-Sánchez, Andrés
AU - Runnacles, Patrício
AU - Zarpellon, Driellen Christine
AU - Kiratcz, Fagner
AU - Campagnoli, Eduardo Bauml
AU - Alegría-Acevedo, Luísa Fernanda
AU - Coelho, Ulisses
AU - Rueggeberg, Frederick Allen
AU - Arrais, Cesar Augusto Galvão
N1 - Publisher Copyright:
© 2020 The Academy of Dental Materials
PY - 2020/9
Y1 - 2020/9
N2 - Objective: To evaluate the influence of light emitted from two Polywave®, LED light-curing units (LCU) on in vivo pulp temperature (PT) rise and signs of acute inflammatory response in pulps of human premolar having deep Class V preparations. Methods: Sixty intact, first premolars from 15 volunteers requiring extraction received infiltrative anesthesia. A sterile thermocouple probe was inserted within the pulp tissue through a minute occlusal pulp exposure in only 45 teeth (n = 9) to continuously monitor PT (°C). A deep buccal Class V preparation was created, and the surface was exposed to light from a commercial Polywave LCU (Bluephase 20i (20i), Ivoclar Vivadent) or from an experimental LCU (Exp) using the exposure modes (EM): 1s/Exp and 2s/Exp, 10s/20i, 20s/20i, and 60s/20i. Peak PT and PT rise values above baseline (ΔT) data were evaluated using a one-way ANOVA followed by Tukey's post-hoc test (α = 5%). Teeth used for histological and immunohistochemical analyses (n = 3) were extracted approximately 2 h after exposure to the LCU. Results: No significant difference in peak PT and ΔT values was noted between 2s/Exp and 20s/20i groups, which both exhibited higher values than 1s/Exp and 10s/20i groups (p < 0.001). Dilated and congested blood vessels were seen after exposure to 1s/Exp, 2s/Exp, or 60s/20i EMs. The expression of IL-1β and TNF-α tended to be more intense when higher irradiance was delivered. Significance: Although higher irradiance delivered over a short exposure caused lower PT rise than 5.5 °C, such EMs should be used with caution, as they have more potential to harm the pulp tissue.
AB - Objective: To evaluate the influence of light emitted from two Polywave®, LED light-curing units (LCU) on in vivo pulp temperature (PT) rise and signs of acute inflammatory response in pulps of human premolar having deep Class V preparations. Methods: Sixty intact, first premolars from 15 volunteers requiring extraction received infiltrative anesthesia. A sterile thermocouple probe was inserted within the pulp tissue through a minute occlusal pulp exposure in only 45 teeth (n = 9) to continuously monitor PT (°C). A deep buccal Class V preparation was created, and the surface was exposed to light from a commercial Polywave LCU (Bluephase 20i (20i), Ivoclar Vivadent) or from an experimental LCU (Exp) using the exposure modes (EM): 1s/Exp and 2s/Exp, 10s/20i, 20s/20i, and 60s/20i. Peak PT and PT rise values above baseline (ΔT) data were evaluated using a one-way ANOVA followed by Tukey's post-hoc test (α = 5%). Teeth used for histological and immunohistochemical analyses (n = 3) were extracted approximately 2 h after exposure to the LCU. Results: No significant difference in peak PT and ΔT values was noted between 2s/Exp and 20s/20i groups, which both exhibited higher values than 1s/Exp and 10s/20i groups (p < 0.001). Dilated and congested blood vessels were seen after exposure to 1s/Exp, 2s/Exp, or 60s/20i EMs. The expression of IL-1β and TNF-α tended to be more intense when higher irradiance was delivered. Significance: Although higher irradiance delivered over a short exposure caused lower PT rise than 5.5 °C, such EMs should be used with caution, as they have more potential to harm the pulp tissue.
KW - Curing light
KW - Histology
KW - Humans
KW - Immunohistochemistry
KW - Pulp temperature
KW - Random allocation
UR - http://www.scopus.com/inward/record.url?scp=85087015640&partnerID=8YFLogxK
U2 - 10.1016/j.dental.2020.05.015
DO - 10.1016/j.dental.2020.05.015
M3 - Artículo
C2 - 32576408
AN - SCOPUS:85087015640
SN - 0109-5641
VL - 36
SP - 1201
EP - 1213
JO - Dental Materials
JF - Dental Materials
IS - 9
ER -