V. M. Abazov, B. S. Acharya, G. D. Alexeev, G. Alkhazov, V. A. Anosov, B. Baldin, S. Banerjee, O. Bardon, J. F. Bartlett, M. A. Baturitsky, D. Beutel, V. A. Bezzubov, V. Bodyagin, J. M. Butler, H. Cease, E. Chi, D. Denisov, S. P. Denisov, H. T. Diehl, S. DoulasS. R. Dugad, O. V. Dvornikov, A. Dyshkant, M. Eads, A. Evdokimov, V. N. Evdokimov, T. Fitzpatrick, M. Fortner, V. Gavrilov, Y. Gershtein, V. Golovtsov, B. Gomez, R. Goodwin, Yu A. Gornushkin, D. R. Green, A. Gupta, S. N. Gurzhiev, G. Gutierrez, H. Haggerty, P. Hanlet, S. Hansen, E. Hazen, D. Hedin, B. Hoeneisen, A. S. Ito, R. Jayanti, K. Johns, N. Jouravlev, A. M. Kalinin, S. D. Kalmani, Y. N. Kharzheev, N. Kirsch, E. V. Komissarov, V. M. Korablev, A. Kostritsky, A. V. Kozelov, M. Kozlovsky, N. P. Kravchuk, M. R. Krishnaswamy, N. A. Kuchinsky, S. Kuleshov, A. Kupco, M. Larwill, R. Leitner, V. V. Lipaev, A. Lobodenko, M. Lokajicek, H. J. Lubatti, E. Machado, M. Maity, V. L. Malyshev, H. S. Mao, M. Marcus, T. Marshall, A. A. Mayorov, R. Mccroskey, Y. P. Merekov, V. A. Mikhailov, N. Mokhov, N. K. Mondal, P. Nagaraj, V. S. Narasimham, A. Narayanan, J. P. Negret, P. Neustroev, A. A. Nozdrin, B. Oshinowo, N. Parashar, N. Parua, V. M. Podstavkov, P. Polozov, S. Y. Porokhovoi, I. K. Prokhorov, M. V.S. Rao, J. Raskowski, L. V. Reddy, T. Regan, C. Rotolo, N. A. Russakovich, B. M. Sabirov, B. Satyanarayana, Y. Scheglov, A. A. Schukin, H. C. Shankar, A. A. Shishkin, D. Shpakov, M. Shupe, V. Simak, V. Sirotenko, G. Smith, K. Smolek, K. Soustruznik, A. Stefanik, J. Steinberg, V. Stolin, D. A. Stoyanova, L. Stutte, J. Temple, N. Terentyev, V. V. Teterin, V. V. Tokmenin, D. Tompkins, L. Uvarov, S. Uvarov, L. A. Vasilyev, L. S. Vertogradov, P. R. Vishwanath, A. Vorobyov, V. B. Vysotsky, H. Willutzki, M. Wobisch, D. R. Wood, R. Yamada, Y. A. Yatsunenko, F. Yoffe, M. Zanabria, T. Zhao, D. Zieminska, A. Zieminski, S. A. Zvyagintsev

Producción científica: Contribución a una revistaArtículorevisión exhaustiva

125 Citas (Scopus)

Resumen

We describe the design, construction, and performance of the upgraded DØ muon system for Run II of the Fermilab Tevatron collider. Significant improvements have been made to the major subsystems of the DØ muon detector: trigger scintillation counters, tracking detectors, and electronics. The Run II central muon detector has a new scintillation counter system inside the iron toroid and an improved scintillation counter system outside the iron toroid. In the forward region, new scintillation counter and tracking systems have been installed. Extensive shielding has been added in the forward region. A large fraction of the muon system electronics is also new.

Idioma originalInglés
Páginas (desde-hasta)372-398
Número de páginas27
PublicaciónNuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
Volumen552
N.º3
DOI
EstadoPublicada - 1 nov. 2005

Huella

Profundice en los temas de investigación de 'The muon system of the Run II DØ detector'. En conjunto forman una huella única.

Citar esto